Description:
|
Tower Top Amplifiers 455-460MHz • Low Loss Filter, Lightning Protection, Bias Tee • Stainless steel canister design for less wind loading and better weather protection • Quadrature ampliflier for better reliability, lower noise and higher IP3 • Receive Signal improvement for long coaxial cable runs • Automatic Bypass of Top Amp dbSpectra 08-2009 Rev. 3 1590 E. Highway 121, Building A • Lewisville, Texas 75056 Ph: 469.322.0080 • Fax: 469.322.0079 • www.dbspectra.com dbSpectra High Preformance Filter Bypass Relay PDU (Order Separately) Freq. Range: TMA Gain: Filter Band Width: TMA Noise Figure: IP3 (AMP only): Return Loss: Power Supply Volt: Operating Current: Surge Suppression: ATS7TMA22 794-816 MHz 19 dB (typ) 22 MHz <2.5 dB (typ) >40 dBm 14 dB (min) 15 VDC (nominal) 500 mA (typ) 18K ANSI C62.1 8/20 WAVEFORM 110 JOULES ATS7TMA30 794-824 MHz 17 dB (typ) 30 MHz <2.7 dB (typ) >40 dBm 14 dB (min) 15 VDC (nominal) 500 mA (typ) 18K ANSI C62.1 8/20 WAVEFORM 110 JOULES ATS8TMA18 806-824 MHz 18 dB (typ) 18 MHz <2.5 dB (typ) >40 dBm 14 dB (min) 15 VDC (nominal) 500 mA (typ) 18K ANSI C62.1 8/20 WAVEFORM 110 JOULES ATS8TMA10 806-816 MHz 18 dB (typ) 10 MHz <2.5 dB (typ) >40 dBm 14 dB (min) 15 VDC (nominal) 500 mA (typ) 18K ANSI C62.1 8/20 WAVEFORM 110 JOULES ATS8TMA3 806-824 MHz 17 dB (typ) 3 MHz 3.5 dB >40 dBm 14 dB (min) 15 VDC (nominal) 500 mA (typ) 18K ANSI C62.1 8/20 WAVEFORM 110 JOULES ATS9TMA5 896-901 MHz 19 dB (typ) 5 MHz <2.5 dB >40 dBm 14 dB (min) 15 VDC (nominal) 500 mA (typ) 18K ANSI C62.1 8/20 WAVEFORM 110 JOULES DB8982Y-TMA 456-460, 466-470 16 dB (typ) 2 @ 4 MHz 4.5 dB (max) >40 dBm 14 dB (min) 15 VDC (nominal) 500 mA (typ) 18K ANSI C62.1 8/20 WAVEFORM 110 JOULES ATS5TMA3 470-512 MHz 16 dB (typ) 3 MHz 4.5 dB (max) >40 dBm 14 dB (min) 15 VDC (nominal) 500 mA (typ) 18K ANSI C62.1 8/20 WAVEFORM 110 JOULES ATS3TMA4 370-400 MHz 14 dB (min) 4 MHz 4.5 dB (max) >40 dBm 14 dB (min) 15 VDC (nominal) 500 mA (typ) 18K ANSI C62.1 8/20 WAVEFORM 110 JOULES Weight: 25 lbs (11.3 kg) Environmental Stealing: NEMA 4X (DB8982Y-TMA / ATS5TMA3 / ATS3TMA4): 59 (26.8) Dimensions (WxDxH): 9 x 13.25 x 21.25 in. Outer Finish: White (UV protected) (229 x 337 x 540 mm) (DB8982Y-TMA) / ATS5TMA3 / 11.5 x 13.25 x 31.25 Standard Mounting Hardware: DB380, Included ATS3TMA4): (292.1 x 336.6 x 793.8) (Weight and dimensions include mounting brackets) RF Connectors: Type N-Female Temp. Range: -30° to 60° C ELECTRICAL MECHANICAL 700-800-900 UHF Amp Bias Tee DC Bias Tee Power Supply Splitter Tower Top Amplifiers UHF, 700, 800, or 900 MHz dbSpectra 08-2009 Rev. 3 1590 E. Highway 121, Building A • Lewisville, Texas 75056 Ph: 469.322.0080 • Fax: 469.322.0079 • www.dbspectra.com dbSpectra Test Signal Injection Option: • Allows a closed loop RF check of the TTA system. • Requires a second RF cable to be installed at site. • Test signal is injected into this second cable at the PDU, Test signal enters TTA RX path via a 30 dB coupler in TMA enclosure. • A test signal injection off/on switch on PDU controls a relay in the TTA which allows the RX antenna to be disconnected if desired from the system during test, or test can be conducted with antenna to avoid disruption to system. • Level of test signal can be measured at RX multicoupler output port. • Top amp can be manually bypassed at PDU to measure closed loop signal level with and without top amp in line to verify operation. • Order TTA unit with “-R” for Test Port • For DBSMCP PDU order with Alarm option that includes test port (see DBSMCP Datasheet) • “Test Port Injection Kit” For DBCNRX PDU order DBCN1NJKT separately Polyphasor/ Bias Tee Polyphasor Polyphasor/ Bias Tee Amp Polyphasor/ Bias Tee DBSMCP PDU & RX MC Test Signal In Test Signal Out at RX Multicoupler Port TTA Enclosure 2nd RF Cable for Test Injection Main RF Cable BOTTOM END ACCESSORIES DBSMCP Series: Power Distribution Unit – providing alarming and power through a Bias Tee. DBCNRX Series: PDU / Receiver Multicoupler package with alarm and Bias Tee ORDERING INFORMATION Add Suffix to TMA Model Number: -R: Test Port- Signal Injector – provides for 2nd transmission line input for testing with control to switch out antenna and switch in Test Port. 50 Ω 30 dB coupler Test Port Injection Relay
|